The person will not be allowed to open the covers and panel of the method, neither Notice: gadget disassemble is authorized. To ensure the process effectiveness and safety, only Mindray engineers or engineers licensed by Mindray can conduct servicing.

iZoom™ permits accurate viewing of graphic from length iWorks™ Protocol aids standardize workflow and lower Test occasions

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Be aware: Be certain that you may pull out and press into the IO board sockets vertically when pulling out and assembling the IO board assembly about the placement of the handle. Take out panhead screws with washers M3X6 (four) accustomed to safe the IO board, and then you might consider out the IO board. Page 116 Take away panhead screws with washers (two M3X6) which can be fixed on the principle device, choose out the higher baffle and after that pull out two cables connecting the principle board to the facility module assembly.

Site 145 Clean user interface Applications: dry tender fabric, delicate soapy drinking water  System:  Use dry soft cloth to scrub the floor on the method. When the procedure is soiled, moisten the soft cloth with delicate soapy h2o and wipe off any stains. Use dry delicate cloth to get rid of any humidity and permit all tough surfaces to completely air-dry. Website page 146: Clean The Peripherals

Operate: Over the again-finish of the leading board, a Unique keep an eye on IC is made use of to watch signal voltages  and clock battery electric power that are supplied to the key board by the most crucial unit box electricity provide module.

Performance Check five.5.one Test Course of action Resolution Detection depth Geometric Position Precision Blackout space take a look at Report the exam pictures 5.5.2 Take a look at Content The graphic employed Here's only for reference, keep on with the graphic influence in the true Notice: situation. Needs: Show: established the distinction and brightness in the clinical application price (or maybe the default standing) Operation natural environment: darkish space, simulating the clinical software environment. Webpage 76 In problem which the transverse resolution tests targets are horizontally displayed, document the minimal distance of two targets that could be Plainly regarded. Repeat the operation over with the transverse resolution screening targets at other depths. As demonstrated in determine beneath. Axial resolution ... Webpage 77 When using the convex probe, hold the transverse resolution screening targets to NOTE: be shown close to the midline. When employing a linear probe with steer function, don't turn on the steer function when carry out the transverse resolution check. Zoom while in the area in which the targets Situated if essential. The diameter in the target point at a specific depth is equal towards the transverse resolution in the depth. Web page seventy eight 5.

five.2.3 Geometric positioning accuracy Longitudinal geometric positioning precision  Test Action: Do changes as the best way in tests the most depth. Report the distance by 20mm Just about every phase about the longitudinal targets line utilizing the measurement caliper; Select the value with the greatest error (to 20mm), compute the accuracy using the components below The measurement caliper must be positioned at the upper fringe of the target, Be aware:... Site seventy nine Transverse geometric positioning accuracy  Check Phase: Deal with the scan floor of your phantom with h2o or few gel, gently Speak to the probe with the scan area Regulate the depth, building the transverse targets being shown while in the picture. Alter the focus position to generally be posited beside the transverse targets (the typical will not be very clear) Adjust parameters like attain, TGC, making Each and every transverse targets for being Evidently displayed. Web page 80 five.five.2.4 Blackout Location Test Stage: Cover the scan area from the phantom with h2o or few gel, Carefully Call the probe Using the scan surface area Regulate the depth in a decreased value, and established the main target at the closest place to the scan floor. Decrease the worth of parameters like AP, Achieve right until the track record sound just might be noticed. Site eighty one: Software Improve And Upkeep

Cookies are crucial to the proper functioning of a web page. To improve your knowledge, we use cookies to remember log-in details and provide protected log-in, accumulate stats to improve web page operation, and provide content material tailored towards your pursuits.

After changing the CPU module, essential file must be produced Once more according to the new MAC deal with and composed into HDD of your equipment. Or else, the configuration operate from the solution might be shed. Following taking away the CPU module, Get rid of panhead screws with washers (12 M3X6) mounted on the principle unit box, you will take from the board. Web page 118 Determine eight-29 Disassemble the Control Panel Assembly (1) Maintain the upper fringe of user interface assembly, and open up up the control panel. Determine eight-thirty Disassemble the User interface Assembly (two) Immediately after eradicating one countersunk head self-tapping screw PT3X10 mounted over the control panel and take out the plug on the keyboard and the leading device connecting cables, you Dp50rb login can take away the user interface assembly.

Webpage forty five Return “Printer Services” website page, Decide on the corresponding provider with the printer list and raise the support. The program integrates motorists of HP printers, following HP printers are related, motorists is going to be mounted immediately (about 10s).If automobile installation fails, icon will Show on the correct reduce corner of your display screen to alert you that guide installation is important. Website page 46: Network Preset

Mindray’s new generation of black & white ultrasound process, DP-50 Professional, is provided with State-of-the-art imaging systems enabling further penetration and more rapidly image acquisition with larger resolution.

Reduce off cable ties connecting the most crucial unit to the display by diagonal slicing pliers, after which you can pull out the corresponding cable plugs.

Your Instrument for further biopsy: making it possible for changes on the scan line to realize better visibility in the needle, nerves and smaller vessels, guaranteeing the continuity of all facts.